VistaQuest N7227V5 User Manual

Page 43

Advertising
background image

– 43 –

The display then returns again to the first screen so that the next relay number
to be programmed can be entered, or enter [0][0] to end relay programming.

Previously entered data can be reviewed by pressing [#] [8] [0]. After the
relay number is chosen, press [

] to go to the next screens. This is a review

mode only, and data cannot be changed.

Example of Output

Relay Programming

A lamp is to be turned on when any one of 3 specific zones are faulted or
when any 24-hour auxiliary zone is disturbed. We want to turn off the
lamp manually without affecting the arming status of the system.

In field *80 we choose Output Relay 01 and program the Ac tion (A) to be "2"
(Close and stay closed). The Event we are looking for to

start the relay action

is a fault, so we will program "2" in (EV). We will use Zone List 1 for the 3
specific zones, so will program "1" in (ZL), (and will program these 3 zones in
field *81's Zone List 1).
The second condition for turning on the indicator is trigger ing a 24 hour aux.
zone (Zone Type 08), so we will program (ZT) as "08".
To

stop relay action and turn off the indicator, we do not want to use a restore

of any zone, so we will program a "0" for the "

Restore of" Zone List (ZL). To

choose a manual entry of User Code + [#] + [7] to turn it off, we will program
(ZT) as "34".
If no other relay is to be programmed we go to field *81 and program the 3
specific zones in Zone List 1.
Press

81. (Zone Lists for Output Relays ). This interactive mode is applicable

only if you have programmed

80 mode.

Refer to the Programming Form worksheet for

81 Mode.

Zone List Displays

Zone List No.

(00 = Quit)

01

Upon keying

81, this screen will appear. Enter the Zone List Number 01, 02,

or 03 to program (or 00 to end these entries). Press the [

] key to advance.

In the following displays, zone list 01 has been selected for programming.

01

Enter Zn Num.

(00 = Quit)

00

Enter each zone number to add to the zone list by first entering the zone
number, then the [

] key (example, 01

, 02

, 03

). After all zones desired

are entered, press 00 to advance.

01 Del Zn List?

0 = No 1 = Yes

0

To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted
automatically. and programming will return to the first screen.
To save the zone list, enter 0 (No) to advance.

01 Delete Zone?

0 = No 1 = Yes

0

To delete a zone or zones in a zone list enter 1 (Yes) to advance.

01 Zn to Delete?

(00 = Quit)

00

Enter each zone to be deleted from the list, followed by the [

] key. After all

zones to be deleted are entered, enter 00 to return to the first screen so that
another list can be programmed, if desired.

Notes:

• Any list may include any or all of the system's zone numbers.

• A zone list can be assigned to more than one output relay.

If you only want to review what has been programmed previously, enter
[#][8][1]. The review can be advanced by using the [

] key. When finished,

enter [0][0]

to quit. No programmed values can be changed in this mode.

When programming in

80 and

81 interactive modes is completed, exit

the programming mode by keying

99.

Advertising