INSTALLING GAS LINE

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

IMPORTANT:

See Connecting to Gas Supply in

your log set owner’s manual for details on gas

hookup.

You may run the gas line from either side of the

firebox (see Figure 11). When you have deter-

mined how the gas line will run, locate one of

the recessed knockouts in the firebrick floor (see

Figure 12). Firmly tap the center of the knockout

with a chisel until it is released. Carefully chisel

the rough edges of the hole you have made to

smooth edges. This hole will line up with the hole

in the metal floor.

CAUTION: Do not use exces-

sive force to remove the knock-

out. Too much force may damage

the firebrick concrete insert.

iNSTaLLaTiON

Continued

A manual shutoff valve, CSA certified and com-

plying with the National Fuel Gas code, ANS

Z223.1/NFPA 54, must be included within (6') six

feet of the vent-free firebox gas supply system. It

may be convenient to install the gas shutoff outside

the vent-free firebox enclosure where it can be

accessed with a key through a wall as shown in

Figure 13. Depending on the type of installation,

some local codes may require you to install two

(2) manual shutoff valves independently accessible

from both rooms. Check your local codes for ap-

plicable installation requirements.

A 36" long 1/2" NPT SCHD 40 flexible gas con-

nector line complying with the National Fuel Gas

code ANS Z223.1/NFPA 54, may be run from the

regulator to the incoming 1/2" NPT black iron

gas line. You may also route the incoming 1/2"

NPT black iron gas line directly to the appliance

regulator.

The incoming gas line may be routed into the vent-

free firebox either from the left or right hand sides

(see Figure 11). Remove the gas line cover plate

from the vent-free firebox’s outer surround at the

location to be used.

Figure 11 - Installing Gas Line and

Manual Shutoff Valve

Manual Shutoff Valve is
Located Under Firebox
Floor on Either Side

Gas Line Installed
Through Access Hole
on One Side of Firebox

Alternative
Gas Line
Location

Figure 12 - Location of Knockouts for

Gas Line

Extension

Key

Shut-Off Valve

Figure 13 - Typical Exterior Wall Gas

Shut-Off Installation

Knockouts

3/4" Thick Liner

Remove This Area

Firebrick Floor