Installation – Vanguard FBST User Manual

Page 13

Advertising
background image

www.desatech.com

105116-01D

13

Figure 15 - Locating Electrical

Connection and Gas Connection on

Either Side of Fireplace

Cover
Plates

Electrical
Connection
Access Hole

Gas Connection
Access Hole

Note:

A 120V supply connection to the leads to

the receptacle must be provided for use with the

optional blower kit whether installed during or

after initial firebox installation. You may not be

able to install a supply connection after the final

installation is completed. Refer to Optional Blower

Assembly Installation for specifics.

iNSTaLLaTiON

Continued

OpTIONAL BLOWER ASSEMBLY
INSTALLATION

Proper installation of the blower system is required

to insure that the maximum discharge of air can

be delivered through the louvers on each side of

the fireplace.
Note:

You may perform this installation from

either side of the fireplace within either room. The

lower door panels are removable from both sides

of the firebox for better access.

1. Remove the blower assembly from the pack-

aging and inspect the fan and wiring for dam-

age. If any wiring is loose or damaged, return

the assembly for exchange to your dealer or

distributor.

2. Remove the 2 screws located at the top of the

lower door panel. Slide door panel forward

and up to remove tabs on panel from locating

slots in firebox (see Figure 16).

3. Locate the two strips of hook and loop mounting

strips on one side of the base of the lower com-

partment. Align the mounting strips on blower

with mounting strips on base of firebox.

4. Install blower housing with exhaust outlet

ports directed upwards along inner side wall of

lower compartment. The blower outlets must

be installed flush to the outer cabinet for air

to flow properly.

5. Apply gentle force between hook and loop

mounting strips to seat blower.

6. Remove control knob and lock nut from

blower speed control shaft.

7. Place speed control shaft through 3/8" hole

provided in right side of lower door panel

removed in step 2.

8. While supporting speed control housing, se-

cure shaft in panel hole with lock nut. Place

control knob on shaft.

9. Plug blower power cord into receptacle lo-

cated in lower firebox compartment. Check

to make sure there are no foreign objects in

blower wheel.

WARNING: Never touch the

blower wheel while in operation.

10. Turn blower on and check for proper operation.

11. Turn blower off before continuing.

12. Replace lower door panel by inserting tabs on

bottom of panel into locating slots on firebox.

Push door panel into an upright position and

secure with screws removed in step 2.

Figure 16 - Removing Lower Door Panel

Locating
Holes

Door Panel

Locating Slot

Locating
Slot

Advertising