1 inspection, 2 package contents, Safety – Westell Technologies Webshare 36R566 User Manual

Page 7: 1 inspection 1.2 package contents, Afety

Advertising
background image

Installation/User Guide

Model # –WebShare

Part # – 030-300109

Rev C

Revision Date – 09/2000

2000 Westell, Inc.

Printed in the USA

030-300109C

6

Multi-port Ethernet 10BaseT hub (for multiple users)

VGA

Monitor

Cross over Ethernet cable for Modem to Ethernet Hub

VPI/VCI Values (provided by your service provider)

PPPoE Support (provided by your service provider)

ADSL signals must be blocked from reaching each telephone, answering machine, fax machine, conventional
computer mode or any similar conventional devices. Failure to do so may degrade telephone voice quality and
ADSL performance. There are two ways to block the ADSL signal from telephone equipment:

Method 1. Microfilters – Install a microfilter at each telephone jack being used for a phone, answering
machine, fax machine or other telephone device. Microfilter installation is simple and requires no tools
or telephone rewiring. Just unplug the telephone device from the baseboard or wall mount and snap in a
microfilter, then snap in the telephone device. Contact Westell to obtain a microfilter kit (Westell part
number A90-36FK201) which contains multiple microfilters for your installation.

Method 2: POTS Splitter – Install a POTS splitter (Westell model 32RTPSGNA1) at the telephone
service entry point. Installation of a POTS splitter may require telephone rewiring, therefore, POTS
splitter installation is typically performed by your service provider. If you choose to use a POTS splitter,
contact your telephone company or service provider for installation.

1.1 Inspection

Upon receipt, thoroughly inspect the unit for damage. If the unit has been damaged during transit, report the
damage immediately to the Transportation Company and Westell Customer Support. The transportation carrier
assumes responsibility for safe delivery of goods. Refer to Section 10 for further information.

1.2 Package Contents

The WebShare Proxy Router is shipped with a power supply and straight through Ethernet cable.

You may have to supply the following cables:

10BaseT crossover cable with RJ45 connectors for Ethernet hub to WebShare Proxy Router

connection

RJ11 modular cable for phone line to WebShare Proxy Router connection

2. Safety

Follow these safety precautions before installing any electronic equipment:


1. Never install any telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected

at the network interface.

4. Use caution when installing or modifying telephone lines.
5. When installed, this equipment is to be used behind devices that provide primary lightning protection.

WARNING

Risk of electric shock. Voltages up to 140 Vdc (with reference to ground)
may be present on telecommunications circuits.