HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Fatal Express Port Error

Audible Beeps: None

Possible Cause: A PCI Express port has experienced a fatal error that caused an
NMI.

Action: Run Insight Diagnostics and replace failed PCI Express boards or reseat
loose PCI Express boards.

Fatal Front Side Bus Error

Audible Beeps: None

Possible Cause: The processor front-side bus experienced a fatal error.

Action: Run Insight Diagnostics and replace any failed processors or reseat an
loose processors.

Fatal Global Protocol Error

Audible Beeps: None

Possible Cause: The system experienced a critical error that caused an NMI.

Action: Run Insight Diagnostics and replaced failed components as indicated.

Fatal Hub Link Error

Audible Beeps: None

Possible Cause: The hub link interface has experienced a critical failure that
caused an NMI.

Action: Run Insight Diagnostics and replace failed components as indicated.