HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Audible Beeps: None

Possible Cause: Required fan not spinning.

Action: Replace the failed fan to provide redundancy, if applicable.

1611-Fan Failure Detected

Audible Beeps: 2 short

Possible Cause: Required fan not installed or spinning.

Action:

1. Check the fans to be sure they are working.

2. Be sure each fan cable is properly connected and each fan is properly seated.

3. If the problem persists, replace the failed fans.

1611-Fan x Failure Detected (Fan Zone CPU)

Audible Beeps: 2 short

Possible Cause: Required fan not installed or spinning.

Action:

1. Check the fans to be sure they are working.

2. Be sure each fan cable is properly connected, if applicable, and each fan is

properly seated.

3. If the problem persists, replace the failed fans.