Wiring diagram – Weslo Daybreak SPRW52464 User Manual

Page 17

Advertising
background image

17

10. SYMPTOM: THE SPA JET UNIT CONTINUES

TO RUN AFTER IT HAS BEEN SHUT OFF

a. To turn the spa jet unit on, press the ON/OFF

control once. To turn the spa jet unit off, press
the control twice. After you press it once, the
spa jet unit will shut off for about 30 seconds,
and restart. Press the control again. The spa
jet unit will remain off for three hours, at which
time it will begin running the filter cycle. At any
time after the spa jet unit has been shut off, the
pump will begin cycling the water if the temper-
ature falls below the minimum setting.

11. SYMPTOM: THE WATER LEVEL DROPS

a. Some water loss due to evaporation is normal.

If rapid water loss occurs, or if you notice wet-
ness on the floor around the DAYBREAK, then
the liner may have a leak. Locate the leak, and
patch it using a pool patch kit that you can pur-
chase at any pool and spa supply store.

b. A clamp or seal inside the spa jet may be

loose. Check the floor around the spa jet unit
for excess water, and watch the spa jet unit
while it is operating to see if water drips from
the spa jet unit housing. If you can identify the
location of the leak inside the spa jet unit, tight-
en the clamp or replace the damaged seal.

12. SYMPTOM: THERE ARE WRINKLES IN THE

LINER

a. Drain the water from the DAYBREAK, until the

water level is below the wrinkles. Smooth out
any wrinkles that you can see. Begin to refill
the DAYBREAK. Be sure to check for new
wrinkles that may form in the spa liner as the
water begins to cover the bottom. Smooth out
any wrinkles toward the sides, and then smooth
the wrinkles to the top. It is normal to have
some wrinkles around the spa jet unit.

WIRING DIAGRAM

POWER

SUPPLY

GFCI

BLACK/HOT

WHITE/NEUTRAL

GREEN/GROUND

TIMER

MOTOR

GROUNDING

CONDUCTOR/LUG

(Pressure Wire

Connector)

See the manufacturerÕs wiring diagram on the pump motor for more information.

Advertising