TABLE 18 -

COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HH060)

OUTDOOR

TEMPERATURE,

°

F

INDOOR WB TEMPERATURE,

°

F

55

57

59

61

63

65

67

69

71

73

75

65

5.4

6.8

8.3

9.8

15.5

21.2

27.0

32.7

70

6.3

7.8

9.2

14.9

20.6

26.2

31.9

75

5.8

7.2

8.6

14.2

19.9

25.5

31.1

80

5.3

6.7

8.0

13.6

19.2

24.8

30.3

85

6.1

7.4

12.9

18.5

24.0

29.6

90

5.8

10.5

15.3

20.0

24.8

95

8.2

12.1

16.1

20.0

100

6.8

10.0

13.1

16.3

105

5.5

7.8

10.2

12.5

110

5.7

7.2

8.8

115

5.0

INDOOR DB

TEMPERATURE,

°

F

HEATING SUPERHEAT AT COMPRESSOR SUCTION,

°

F

-10

0

10

20

30

40

50

60

55

2.9

3.1

3.7

5.3

9.4

20.0

70

6.6

17.3

80

10.2

TABLE 19 -

HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HH060)