Table 3, Fig. 2 - typical field wiring diagram – York B1HH018 User Manual

Page 4

Advertising
background image

66297-YIM-C-0205

4

Unitary Products Group

TABLE 3 -

PHYSICAL DATA

MODELS

BHH

018

024

030

036

042

048

060

INDOOR

BLOWER

CENTRIFUGAL BLOWER (Dia. x Wd. in.)

9 X 6

10 X 8

10 X 8

10 x 8

11 x 10

11 x 10

11 x 10

FAN MOTOR HP (Three Speed)







!

"

!

"

!

"

1

INDOOR

COIL

ROWS DEEP

2

2

3

3

3

3

3

FINS PER INCH

15

15

13

15

16

16

16

FACE AREA (Sq. Ft.)

4.38

4.38

4.38

4.38

5.63

5.63

5.63

OUTDOOR

FAN

PROPELLER DIA. (in.)

22

22

22

22

22

22

22

FAN MOTOR HP



"



"



"



"



"



"



"

NOM. CFM TOTAL

1,800

1.800

1,800

2,400

2,400

3,000

3,000

OUTDOOR

COIL

ROWS DEEP

1

1

1

2

2

2

2

FINS PER INCH

20

20

20

20

20

20

20

FACE AREA (Sq. Ft.)

8.3

11.7

11.7

11.7

16.4

16.4

16.4

CHARGE

REFRIGERANT 22 (lbs./oz.)

5 / 6

5 / 5

6 / 5

8 / 12

11 / 8

12 / 0

9 / 0

FILTER

FACE AREA (Sq. Ft. / Qty. / Size)

4.28 / 2 / 14" x 22"

COMPRESSOR HERMETIC Type, (Qty. = 1)

Reciprocating Reciprocating

Scroll

Scroll

Scroll

Scroll

Scroll

FIG. 2 - TYPICAL FIELD WIRING DIAGRAM

POWER WIRING

REFER TO ELECTRICAL DATA

TABLES TO SIZE THE DISCON-

NECT SWITCH, WIRING &

OVERCURRENT PROTECTION.

REFER TO ELECTRICAL DATA

TABLES TO SIZE THE DISCON-

NECT SWITCH, WIRING &

OVERCURRENT PROTECTION.

R

G

W

R

C

Y

Y

W 2

C

W 1

O

O

G

24 VOLT TRANSFORMER

UNIT TERMINAL STRIP

THERMOSTAT

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper operation after servicing.

** = Minimum wire size of 18 AWG

wire should be used for all field
installed 24 volt wire.

**

* = Only required on units with

supplemental electric heat.

*

CONTROL WIRING

NOTE:
HEAT ANTICIPATOR
SHOULD BE SET AT 0.25
AMPS FOR ALL MODELS.

PROGRAMMABLE

THERMOSTAT ONLY