MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI

• HARMONIC CONTENT applies adjustment to the resonance value that

is set by the voice. This parameter specifies relative change with the
value of 64 producing 0 adjustment. As values get higher the sound
becomes increasingly eccentric. Note that for some voices the effective
parameter range is narrower than the legal parameter range.

• RELEASE TIME applies adjustment to the envelope release time set by

the voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.

• ATTACK TIME applies adjustment to the envelope attack time set by the

voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.

• BRIGHTNESS applies adjustment to the cut-off frequency set by the

voice. This parameter specifies relative change with the value of 64
producing 0 adjustment. Lower voices produce a softer sound. For some
voices the effective parameter range is narrower than the legal
parameter range.

(3-2) CHANNEL MODE MESSAGES

STATUS

1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER

CONTROL NUMBER

0ccccccc

c = CONTROL NUMBER

CONTROL VALUE

0vvvvvvv

v = DATA VALUE

(3-2-1) ALL SOUND OFF (Receive only)

(CONTROL NUMBER = 78H , DATA VALUE = 0)

Switches off all sound from the channel. Reset Note On and Hold On conditions established
by Channel Messages.

(3-2-2) RESET ALL CONTROLLERS (Receive only)

(CONTROL NUMBER = 79H , DATA VALUE = 0)

Resets controllers as follows.

PITCH BEND CHANGE

0 (Center)

AFTER TOUCH

0 (min.)

MODULATION

0 (min.)

EXPRESSION

127 (max.)

SUSTAIN

0 (off)

SOSTENUTO

0 (off)

SOFT PEDAL

0 (off)

NRPN

Sets number to null. (Internal data remains unchanged)

RPN

Sets number to null. (Internal data remains unchanged)

PORTAMENT CONTROL

Resets portamento source note number

PORTAMENTO

0 (off)

(3-2-3) ALL NOTES OFF (Receive only)

(CONTROL NUMBER = 7BH , DATA VALUE = 0)

Switches off all of the channel’s “on” notes. However, any notes being held by SUSTAIN or
SOSTENUTO continue to sound until SUSTAIN/SOSTENUTO goes off.

(3-2-4) OMNI OFF (Receive only) (CONTROL NUMBER = 7CH , DATA VALUE = 0)

Same processing as for All Notes Off.

(3-2-5) OMNI ON (Receive only) (CONTROL NUMBER = 7DH , DATA VALUE = 0)

Same processing as for All Notes Off. Omni On is not executed.

(3-2-6) MONO (Receive only) (CONTROL NUMBER = 7EH , DATA VALUE = 0)

Same processing as for All Notes Off. If the 3rd byte is in a range of 0-16 the corresponding
channel will be changed to Mode 4 (m=1).

(3-2-7) POLY (Receive only) (CONTROL NUMBER = 7FH , DATA VALUE = 0)

Same processing as for All Sounds Off and the corresponding channel will be changed to
Mode 3.

(3-3) REGISTERED PARAMETER NUMBER(RPN)

STATUS

1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER

RPN LSB

01100100(64H)

RPN LSB NUMBER

0ppppppp

p = RPN LSB

(refer to the list below)

RPN MSB

01100101(65H)

RPN MSB NUMBER

0qqqqqqq

q = RPN MSB

(refer to the list below)

DATA ENTRY MSB

00000110(06H)

DATA VALUE

0mmmmmmm

m = Data Value

DATA ENTRY LSB

00100110(26H)

DATA VALUE

0lllllll

l = Data Value

First appoints the parameter for RPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.

RPN

D.ENTRY

LSB MSB

MSB

LSB

PARAMETER NAME

DATA RANGE

00H 00H

mmH

PITCH BEND SENSITIVITY

00H-18H

(0 - 24 semitones)

01H 00H

mmH

llH

FINE TUNE

{mmH,llH} = {00H,00H}-{40H,00H}-{7FH,7FH}

(-8192*100/8192) - 0 - (+8192*100/8192)

02H 00H

mmH

COARSE TUNE

28H - 40H - 58H (-24 - 0 - +24 semitones)

7FH 7FH

NULL

Clears the current RPN number setting.
Does not change the internal parameter settings.

(3-4) NON-REGISTERED PARAMETER NUMBER(NRPN) (Receive only)

STATUS

1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER

NRPN LSB

01100010(62H)

NRPN LSB NUMBER

0ppppppp

p = NRPN LSB

(refer to the list below)

NRPN MSB

01100011(63H)

NRPN MSB NUMBER

0qqqqqqq

q = NRPN MSB

(refer to the list below)

DATA ENTRY MSB

00000110(06H)

DATA VALUE

0mmmmmmm

m = Data Value

First appoints the parameter for NRPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.

NRPN

D.ENTRY

MSB LSB MSB LSB

PARAMETER NAME DATA RANGE

01H 08H

mmH

VIBRATO RATE

00H - 40H - 7FH (-64 - 0 - +63)

01H 09H

mmH

VIBRATO DEPTH

00H - 40H - 7FH (-64 - 0 - +63)

01H 0AH

mmH

VIBRATO DELAY

00H - 40H - 7FH (-64 - 0 - +63)

01H 20H

mmH

FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)

01H 21H

mmH

FILTER RESONANCE

00H - 40H - 7FH (-64 - 0 - +63)

01H 30H

mmH

EQ BASS

(CVP-109/107/700)

00H - 40H - 7FH (-64 - 0 - +63)

01H 31H

mmH

EQ TREBLE

(CVP-109/107/700)

00H - 40H - 7FH (-64 - 0 - +63)

01H 34H

mmH

EQ BASS FREQ.

(CVP-109/107/700)

00H - 40H - 7FH (-64 - 0 - +63)

01H 35H

mmH

EQ TREBLE FREQ.

(CVP-109/107/700)

00H - 40H - 7FH (-64 - 0 - +63)

01H 63H

mmH

EG ATTACK TIME

00H - 40H - 7FH (-64 - 0 - +63)

01H 64H

mmH

EG DECAY TIME

00H - 40H - 7FH (-64 - 0 - +63)

01H 66H

mmH

EG RELEASE

00H - 40H - 7FH (-64 - 0 - +63)

14H rrH

mmH

DRUM FILTER CUTOFF FREQ. 00H - 40H - 7FH (-64 - 0 - +63)

15H rrH

mmH

DRUM FILTER RESONANCE

00H - 40H - 7FH (-64 - 0 - +63)

16H rrH

mmH

DRUM AEG ATTACK RATE 00H - 40H - 7FH (-64 - 0 - +63)

17H rrH

mmH

DRUM AEG DECAY RATE

00H - 40H - 7FH (-64 - 0 - +63)

18H rrH

mmH

DRUM PITCH COARSE

00H - 40H - 7FH (-64 - 0 - +63)

19H rrH

mmH

DRUM PITCH FINE

00H - 40H - 7FH (-64 - 0 - +63)

1AH rrH

mmH

DRUM LEVEL

00H - 7FH (0 - max.)

1CH rrH

mmH

DRUM PANPOT

00H ,01H - 40H - 7FH

(random,left - center - right)

1DH rrH

mmH

DRUM REVERB SEND LEVEL

00H - 7FH (0 - max.)

1EH rrH

mmH

DRUM CHORUS SEND LEVEL

00H - 7FH (0 - max.)

1FH rrH

mmH

DRUM VARIATION SEND LEVEL 00H - 7FH (0 - max.)

The MSB 14H-1FH (for drums) message is received when multi-part parameters PART
MODE = DRUMS1...2.

rrH :

drum instrument note number

(3-5) SYSTEM REALTIME MESSAGES

(3-5-1) MIDI CLOCK

STATUS

11111000 (F8H)

Transmission: 96 clocks per measure are transmitted.
Reception: If the instrument’s clock is set to external, after FAH is received from the external
device the instrument’s clock will sync with the 96 beats per measure received from the external
device.
Decides whether the internal clock, or Timing Clocks received via the MIDI IN will be used.

(3-5-2) START

STATUS

11111010 (FAH)

Transmission: Transmitted when instrument’s Rhythm or Song playback is started.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will start.

(3-5-3) STOP

STATUS

11111100 (FCH)

Transmission: Transmitted when instrument’s Rhythm or Song playback is stopped.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will stop.

(3-5-4) ACTIVE SENSING

STATUS

11111110 (FEH)

Transmission: Transmitted approximately once every 200msec.
Reception: Sensing is started once this Code is received. If Status or Data is not received within
400ms, the MIDI Receive Buffer will be cleared, and all notes, including those being sustained,
will be cut OFF. Also, all control values will be reset to their factory defaults.