Table 1-7 – Yamaha CVP-107 EU User Manual

Page 26

Advertising
background image

CVP-109/107/105/103/700

26

○ ○

MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI

03

0n

30

2

00..7F

Ins. Param.1 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.1 LSB

Refer to the Ef. Parameter List

03

0n

32

2

00..7F

Ins. Param.2 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.2 LSB

Refer to the Ef. Parameter List

03

0n

34

2

00..7F

Ins. Param.3 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.3 LSB

Refer to the Ef. Parameter List

03

0n

36

2

00..7F

Ins. Param.4 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.4 LSB

Refer to the Ef. Parameter List

03

0n

38

2

00..7F

Ins. Param.5 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.5 LSB

Refer to the Ef. Parameter List

03

0n

3A

2

00..7F

Ins. Param.6 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.6 LSB

Refer to the Ef. Parameter List

03

0n

3C

2

00..7F

Ins. Param.7 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.7 LSB

Refer to the Ef. Parameter List

03

0n

3E

2

00..7F

Ins. Param.8 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.8 LSB

Refer to the Ef. Parameter List

03

0n

40

2

00..7F

Ins. Param.9 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.9 LSB

Refer to the Ef. Parameter List

03

0n

42

2

00..7F

Ins. Param.10 MSB

Refer to the Ef. Parameter List

00..7F

Ins. Param.10 LSB

Refer to the Ef. Parameter List

TOTAL SIZE 14

For effect types that do not require MSB, the Parameters for Address 02-0B will be received. Address 30-42 will not be received.
For effect types that require MSB, the Parameters for Address 30-42 will be received. Address 02-0B will not be received.
When Bulk Dumps that include Effect Type data are transmitted, the Parameters for Address 02 - 0B will always be transmitted. But, effects that require MSB, when the bulk dump is received the
Parameters for Address 02 - 0B will not be received.

n = Insertion Effect No. (0 - 2)

The INSERTION EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a Parameter Request or Bulk Request message is received, the currently set value is always transmitted.

< Table 1-7 >

MIDI PARAMETER CHANGE TABLE (SPECIAL EFFECT) (CVP-109/107/700)

Address

Size

Data

Parameter

Description

Default

(H)

(H)

(H)

04

00

00

2

00 - 7F

Insertion Effect Type MSB

Refer to the XG Effect Map

00 - 7F

Insertion Effect Type LSB

00 : basic type

02

1

00 - 7F

Insertion Effect Parameter1

Refer to the XG Ef. Parameter List

03

1

00 - 7F

Insertion Effect Parameter2

Refer to the XG Ef. Parameter List

04

1

00 - 7F

Insertion Effect Parameter3

Refer to the XG Ef. Parameter List

05

1

00 - 7F

Insertion Effect Parameter4

Refer to the XG Ef. Parameter List

06

1

00 - 7F

Insertion Effect Parameter5

Refer to the XG Ef. Parameter List

07

1

00 - 7F

Insertion Effect Parameter6

Refer to the XG Ef. Parameter List

08

1

00 - 7F

Insertion Effect Parameter7

Refer to the XG Ef. Parameter List

09

1

00 - 7F

Insertion Effect Parameter8

Refer to the XG Ef. Parameter List

0A

1

00 - 7F

Insertion Effect Parameter9

Refer to the XG Ef. Parameter List

0B

1

00 - 7F

Insertion Effect Parameter10

Refer to the XG Ef. Parameter List

0C

1

00 - 7F

Insertion Effect Part

Part1...16(0...15)

AD1(64)

OFF(16...63, 65...127)

0D

1

00 - 7F

MW Insertion Control Depth

Don’t care

0E

1

00 - 7F

BEND Insertion Control Depth

Don’t care

0F

1

00 - 7F

CAT Insertion Control Depth

Don’t care

10

1

00 - 7F

AC1 Insertion Control Depth

Don’t care

11

1

00 - 7F

AC2 Insertion Control Depth

Don’t care

TOTAL SIZE

12

04

00

14

1

00 - 7F

Unique Insertion Effect External

1...16(0...15), off(127)

Control CH1(Harmony Channel)

15

1

00 - 7F

Unique Insertion Effect External

1...16(0...15), off(127)

Control CH2 (MELODY CHANNEL)

TOTAL SIZE

2

04

00

20

1

00 - 7F

Insertion Effect Parameter11

Refer to the XG Ef. Parameter List

21

1

00 - 7F

Insertion Effect Parameter12

Refer to the XG Ef. Parameter List

22

1

00 - 7F

Insertion Effect Parameter13

Refer to the XG Ef. Parameter List

23

1

00 - 7F

Insertion Effect Parameter14

Refer to the XG Ef. Parameter List

24

1

00 - 7F

Insertion Effect Parameter15

Refer to the XG Ef. Parameter List

25

1

00 - 7F

Insertion Effect Parameter16

Refer to the XG Ef. Parameter List

TOTAL SIZE

6

Insertion Effect Type MSB: Assigns the Harmony Mode.

If the value is not a Harmony Mode value, the Harmony function will be OFF and the input signal will be transmitted as is.

Insertion Effect Type LSB:

Assigns the Harmony Kit.
If the value is not an existing harmony kit value, don’t care.

Harmony Channel:

Harmony control channel.

Melody Channel:

Melody play channel.
When both are received, the last message received will take priority.
For example, when the Melody Channel is 3 and the Harmony Channel 3 message is received, the Melody Channel will be OFF and the Harmony Channel will be 3.

Note) The SPECIAL EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a request message is received, the currently set value is always transmitted.

Advertising