Communications Protocol

The Encore 2 supports RTS/CTS (hardware) and XON/

XOFF handshaking protocols to synchronize with the
host terminal. The handshaking protocol and the baud
rate is programmable. The default communications
parameters are:

Handshaking = RTS/CTS

Baud Rate = 9,600

Parity = None

Data Bits = 8

Stop Bits = 1

Pin Assignments

The following are the pin assignments for the 8-pin DIN

RS232C serial connector.

Pin

Pin

Signal

Signal

Number Name

Type

Description

1

RXD

input

Receive Data

2

TXD

output

Transmit Data

3

CTS

input

Clear To Send from host

4

RTS

output

Request To Send

set high when printer
is ready to accept command/
data

5

GND

Ground

6

NC

No Connect

7

DSR

input

Data Set Ready

Low to high transition turns
printer on, High to low
transition turns printer off
(if enabled)

8

DTR

output

Data Terminal Ready

set high when printer is on

(set to battery voltage for
“S” versions)