A. EARTH CONTINUITY CHECK

A. EARTH CONTINUITY CHECK

A. EARTH CONTINUITY CHECK

A. EARTH CONTINUITY CHECK

A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms)
x 1 scale and adjust zero if necessary.

— Test leads from any appliance earth point to earth pin on plug.

Resistance should be less than 0.1 W (Ohm), check all earth wires
for continuity and all contacts clean and tight.

B. INSULA

B. INSULA

B. INSULA

B. INSULA

B. INSULATION CHECK

TION CHECK

TION CHECK

TION CHECK

TION CHECK

Appliance electrically disconnected, all switches ON.

a) meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads
«0» then there is a short circuit.

b) meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than ×
(infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated
- a detailed continuity check (i.e. by disconnecting and checking each
component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but
no fault could be found under test. However a detailed visual inspection
should reveal evidence of burning around the fault.