c. Install a 8” exhaust duct and extend length = S - 16“

5/8 from ceiling. Duct shall be securely fastened to

joists. Do not use duct smaller than specified.

Attention: Duct installation is not required for non-

vented (recirculating) installations

d. Install 1/2" electrical conduit in location marked on

template and extend length = S - 11“ 1/8 from

ceiling.

Note: If a Remote ventilator installation is required/

needed, then provide an additional hole/conduit.

e. Install drywall around duct and conduit; then refinish

ceiling, leave enough clearance for easy installation

of chimney structure up to ceiling (see Installation

step 6).

f. Tape Template in place and fit 4 screws on mounting

holes, do not tighten but leave a space of 1/2“,

remove the template.

3. Regulate chimney structure according dimension S

(see step 1) and fix all assembly parts with 4 screws

to each bracket (32 screws in total - 8 already in

place , 24 to be screwed in), check structure is well

assembled.

5

Total 8 x 4 screws

4

1

2

3

6

7

8

FRONT

4. For non-vented (recirculating) installations ONLY:

Fix the deflector on the chimney structure.

5. Note: disregard this step if is intended to install

a remote ventilator.

Purchase and install the Integral ventilator (see

paragraph „Before installing the hood - Parts

not supplied“ for model reference).

6. Raise chimney structure up to ceiling (keep 1/

2“ conduit and 8“ duct inside the proper

passage), use the 4 screws (see step 2/e and 2/

f) to hang the hood.

Note: Chimeny structure front corresponds to

side with electronic box.

WARNING

Excessive Weight Hazard

Use two or more people to move and install

range hood.

Failure to do so can result in back or other

injury.

Make final angular adjustment to structure at

ceiling if necessary then securely tighten 4

ceiling lag screws.

Fit two additional screws for definitive fixing.

Lag

screws

Lag

screws

Definitive

fixing

Conduit

passage

Duct

passage

7. Connect ducting to transition. Seal with duct

tape.

Do not use duct smaller than the transition.

For Ductless - recirculating - installations only:

provide and install a duct to connect hood transition

to deflector (the deflector is available as an extra

kit).

Inst

allation