Inst allation – Zephyr EOT-E42ASX User Manual

Page 12

Advertising
background image

12

8. Electrical connection

WARNING

Electrical Shock Hazard

Warning: Turn off power circuit at the service panel

before wiring this unit.

120 VAC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS FITTED WITH AN ELECTRICAL

JUNCTION BOX WITH 3 WIRES, ONE OF WHICH

(GREEN/YELLOW) SERVES TO GROUND THE

APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC

SHOCK, THE GREEN AND YELLOW WIRE MUST BE

CONNECTED TO THE GROUNDING WIRE IN YOUR

HOME ELECTRICAL SYSTEM, AND IT MUST UNDER

NO CIRCUMSTANCES BE CUT OR REMOVED.

Failure to do so can result in death or electrical

shock.

Facing the front of the range hood, remove the left

knockout and the Junction box cover and install the

conduit connector (cULUS listed) in junction box.

knockout

J-Box

cover

Run 3 wires; black, white and green ,according to the

National Electrical Code and local codes and

ordinances, in 1/2" conduit from service panel to

junction box.

J-Box cover

Conduit

Connect black wire from service panel to black or red in

junction box, white to white and green to green-yellow.

Close junction box cover.

9. Note: disregard this step if the hood has been fitted

with an integralventilator.

Purchase and install a Remote ventilator (see

paragraph „Before installing the hood - Parts not

supplied“ for model reference).

10. For non-vented (recirculating) installations ONLY:

Install one charcoal filter.

11. Assemble the canopy with the integral ventilator

housing (chimney structure):

a. Remove the grease filter (see also Care & Use

section - Charcoal filter).

b. Thread completely the lower part of the hood

onto the integral ventilator housing rails.

Note: control panel on canopy and electronic

box on chimney structure should be on the same

side.

c. Make alla cable connections:

LAMPS

CONTROL

PANEL