Adjust media sensors, R to, For addit – Zebra Technologies R170XiTM User Manual

Page 49

Advertising
background image

Printer Operation

Adjust Media Sensors

23063L-003 Rev. 2 12/23/04

R110Xi/R170Xi User Guide

37

Adjust Media Sensors

The transmissive sensor consists of two sections: a light source (the lower media sensor) and a
light sensor (the upper media sensor). The media passes between the two.

Adjust these sensors only when the printer cannot detect the top of the label. The front panel
LCD displays

ERROR CONDITION PAPER OUT

, even though there are labels loaded in

the printer.

To adjust the upper media sensor for the inside half of the media, complete
these steps:

1.

Remove the ribbon (if ribbon is used).

2.

Locate the upper media sensor (

Figure 27

). The upper media sensor eye is directly below

the adjustment screw head.

Figure 27 • Upper Media Sensor Location

3.

Using a Phillips-head screwdriver, slightly loosen the upper media sensor adjustment
screw.

4.

Using the tip of the screwdriver, slide the upper sensor along the slot to the desired
position (for non-continuous media with a notch or hole in the media, the sensor must be
directly above the notch or hole).

5.

Tighten the adjustment screw to secure the upper media sensor.

Note •

T

he upper media sensor can be positioned along the inside half of the media (the side

closest to the back of the printer) or the outside half of the media (the side farthest from the
back of the printer).

1

Upper media sensor adjustment screw

2

Upper media sensor

1

2