Gpi in calibration, Network settings ("6. network setup"), Ip address mode setting – Yamaha ACD1 User Manual

Page 16: Ip address setting, Checking the mac address, Utility, Gpi calibration”), Network settings (“6. network setup”), Network setup, Ip address mode”)

Advertising
background image

ACD1 Reference Manual

16

Panel operations

GPI IN calibration (“5. Utility” “GPI Calibration”)

Calibrates the detected range of the [GPI IN] connector input voltage.

Here you can make network settings for the ACD1.

IP Address Mode setting (“6. Network Setup” “IP Address Mode”)

This specifies whether the ACD1’s IP address will be set automatically by
Amp Editor’s Network Setup or a DHCP server, or manually.

• If you’re using a DHCP server, start up the DHCP server before the ACD1.

• For details on this mode, refer to the Amp Editor owner’s manual.

IP Address setting (“6. Network Setup” “IP Address”)

If the IP Address Mode is Manual, the ACD1’s IP address will be specified
manually.
If the IP Address Mode is DHCP, the assigned IP address will be displayed.

• If the IP Address mode is DHCP, the manually assigned IP address will be ignored.

Checking the MAC address (“6. Network Setup” “MAC Address”)

This displays the MAC address of the ACD1’s [NETWORK] connector.

Parameter

Range

Explanation

Port No.

1–4

Selects the port of the [GPI IN] connector that will be calibrated.

Minimum/maximum
value setting

Min/Max

Selects whether you will be setting the minimum (Min) or maximum (Max) value for
the input voltage.

Voltage value

--

Indicates the input voltage.
At the left of the “–>” symbol is shown the specified voltage (maximum/minimum
value), and at the right is shown the current input voltage. When you confirm the set-
ting, the current input voltage will be assigned as the maximum/minimum value.

Network settings (“6. Network Setup”)

Parameter

Range

Explanation

IP Address Mode

DHCP

The address will be set automatically. If you power-off in this mode, the IP address
setting will be cleared.

Manual

The address will be set manually. In this mode, the IP address setting will be saved
even if you power-off.

Parameter

Range

Explanation

IP Address

001.000.000.001–223.255.255.254

Specifies the ACD1’s IP address.

å

Port No.:

3

Min:3.4V->4.2V

å

6.Network Setup

IP Address Mode

å

IP Address Mode

DHCP

NOTE

å

IP Address

192.168.000.002

NOTE

MAC Address

00A0DE251500

Advertising