Control i/o, Pin assignment, Monitor/remote – Yamaha ACD1 User Manual

Page 23: Data port, Monitor/remote ■ data port, Appendix

Advertising
background image

ACD1 Reference Manual

23

Appendix

*1 Supported models

XP7000, XP5000, XP3500, XP2500, XP1000, XM4180, XM4080, XH200
Guaranteed cable length: 50m

*2 Supported models

T5n, T4n, T3n, PC9501N, PC6501N, PC4801N, PC3301N, PC2001N, PC9500N, PC4800N, PC3300N

*3 Inputs: 4channels, Outputs: 4channels

Outputs: Withstanding Voltage Vmax = 12V (Open)
Outputs: Sink Current Imax = 75mA/pin (Closed)
+V: Imax =100mA/2pins

*4 Input: Imax = 1A, Vmax = 30VDC

MONITOR/REMOTE

DATA PORT

Control I/O

Terminal

Format

Level

Connector

MONITOR/REMOTE

*1

D-SUB 15P (Female)

× 8

DATA PORT

*2

RS-485

RS-485

RJ-45

GPI

*3

IN

0–5 V

Euroblock

(3.5 mm pitch)

OUT

Open Collector

+V

5 V

FAULT OUTPUT

*4

NETWORK

IEEE 802.3

10Base-T/100Base-TX

RJ-45

Pin Assignment

1

GND

2

REMOTE CONTROL

STANDBY

3

MONITOR

MODEL ID

4

REMOTE CONTROL

MUTE CH D

5

MUTE CH C

6

MUTE CH B

7

MUTE CH A

8

MONITOR

PROTECT STATUS CH D

9

PROTECT STATUS CH C

10

PROTECT STATUS CH B

11

PROTECT STATUS CH A

12

OUTPUT LEVEL CH D

13

OUTPUT LEVEL CH C

14

OUTPUT LEVEL CH B

15

OUTPUT LEVEL CH A

1

NC

2

NC

3

NC

4

RxD/TxD -

5

RxD/TxD +

6

NC

7

GND

8

GND

5

4

3

2

1

10

9

8

7

6

15

14

13

12

11

8

1