Connector wiring

You can connect a lamp etc. to the rear panel [FAULT OUTPUT] connector to

indicate that an abnormality has occurred.

The [FAULT OUTPUT] connector consists of NO (Normally Open), C (Common), and
NC (Normally Closed). The [FAULT OUTPUT] connector is a relay circuit, and oper-
ates as follows.

The relay contacts used in the [FAULT OUTPUT] connector are rated for a load of 1A, DC 30V. Do not apply a load that
exceeds this rating.
Use Amp Editor to make settings for the [FAULT OUTPUT] connector.
Euroblock plugs are used for the [FAULT OUTPUT] connector. Euroblock connection methods are described in

“Euroblock

plug connection” (page 18)

in this manual.

• In Amp Editor’s [Device Setup] menu

➝ [Alert Setup], you can set Type to Fault so that a fault can be indicated by a con-

nected lamp, etc. For details on making settings, refer to the “Amp Editor owner’s manual.”

• The relay contacts are rated for a resistive load of 1A, DC 30V. Do not apply a load that exceeds this rating.

FAULT OUTPUT connector

Normal state

Abnormal state

Powered-off

NO

Open

Closed

Closed

NC

Closed

Open

Open

Example : Using an LED to indicate normal/fault status of the ACD1

NOTE

C

NC

NO

C

NC

NO

Normal state

Lit

Powered-off / Abnormal state

ACD1

ACD1

Unlit

Unlit

Lit