Chapter 15 Maintenance Screens

NSA210 User’s Guide

307

Minimum UPS
Capacity

When you use an APC Uninterruptible Power Supply (UPS) with a USB
connection to the NSA, the NSA shuts itself down if the APC UPS’s
battery charge gets down to the percentage you specify in this field. This
allows the NSA to shut down properly and avoid data loss caused by a
power failure when the UPS stops supplying power.

A setting around 50% is recommended. A setting close to 100% is not
recommended since it would cause the NSA to shut down whenever the
UPS is charging. A setting close to 0 is also not recommended since the
UPS would not have enough power to allow the NSA to shutdown
properly.

Apply

Click this to save your changes in this section.

Power On After
Power Failure

Select an option to set whether or not the NSA restarts when the power
is restored after a power failure.

Keep Former
Status

Select this option to have the NSA automatically restart only if it was
operating when the power failed. The NSA remains off if it was already
off when the power failed.

Always Power
On

Select this option to keep the NSA operating as much of the time as
possible. The NSA restarts automatically even if it was turned off when
the power failed.

Always Power
Off

Select this option to keep the NSA from automatically restarting when
the power is restored after a power failure. This is a computer’s
“traditional” behavior. Select this if you have other servers such as a
domain controller or DNS server that you want to start or check after a
power failure before the NSA turns on.

Apply

Click this to save your changes in this section.

Power On/Off Schedule
Enable Power
Control
Schedule

Select this option to have the NSA turn itself off and on or reboot
according to the schedules you configured.

Click Edit to go to the screen where you can configure the power control
schedules.

Refer to

Section 15.3.1 on page 308

for this screen.

Apply

Click this to save your changes in this section.

Table 95 Maintenance > Power Management (continued)