CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.

HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils

UNIT

MODEL*

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

YHJD18S21S1

FC/MC/PC/UC18

17.0 3.26 1.54 9.0 2.18 1.23 7.70

FC/MC/PC/UC24

17.0 3.26 1.54 9.0 2.18 1.23 7.70

FC/MC/PC/UC30

17.0 3.26 1.54 9.0 2.18 1.23 7.70

HC18

17.0 3.26 1.54 9.0 2.18 1.23 7.70

YHJD24S21S1

FC/MC/PC/UC24

23.0 3.72 1.82 12.0 2.44 1.47 7.70

FC/MC/PC/UC30

23.0 3.72 1.82 12.0 2.44 1.47 7.70

FC/MC/PC/UC32

23.0 3.72 1.82 12.0 2.44 1.47 7.70

FC/MC/PC/UC35

23.0 3.72 1.82 12.0 2.44 1.47 7.70

HC30

23.0 3.72 1.82 12.0 2.44 1.47 7.70

HC36

23.0 3.72 1.82 12.0 2.44 1.47 7.70

HD24

23.0 3.72 1.82 12.0 2.44 1.47 7.70

MH24S

23.0 3.72 1.82 12.0 2.44 1.47 7.70

MH30S

23.0 3.72 1.82 12.0 2.44 1.47 7.70

YHJD30S21S1

FC/MC/PC/UC32

29.0 3.56 2.40 15.0 2.24 1.96 7.70

FC/MC/PC/UC35

29.0 3.56 2.40 15.0 2.24 1.96 7.70

FC/MC/PC/UC37

29.0 3.56 2.40 15.0 2.24 1.96 7.70

FC/MC/PC/UC43

29.0 3.56 2.40 15.0 2.24 1.96 7.70

HC36

29.0 3.56 2.40 15.0 2.24 1.96 7.70

HC42

29.0 3.56 2.40 15.0 2.24 1.96 7.70

HD36

29.0 3.56 2.40 15.0 2.24 1.96 7.70

MH24S

29.0 3.56 2.40 15.0 2.24 1.96 7.70

MH30S

29.0 3.56 2.40 15.0 2.24 1.96 7.70

YHJD36S21S1

FC/MC/PC/UC37

34.0 3.58 2.78 21.0 2.52 2.39 8.50

FC/MC/PC/UC43

34.0 3.58 2.78 21.0 2.52 2.39 8.50

FC/MC/PC/UC48

34.0 3.58 2.78 21.0 2.52 2.39 8.50

FC/MC/PC/UC60

34.0 3.58 2.78 21.0 2.52 2.39 8.50

HC42

34.0 3.58 2.78 21.0 2.52 2.39 8.50

HC60

34.0 3.58 2.78 21.0 2.52 2.39 8.50

HD48

34.0 3.58 2.78 21.0 2.52 2.39 8.50

HD60

34.0 3.58 2.78 21.0 2.52 2.39 8.50

YHJD42S21S1

FC/MC/PC/UC48

42.0 3.52 3.45 25.0 2.60 2.81 8.50

FC/MC/PC/UC60

42.0 3.52 3.45 25.0 2.60 2.81 8.50

HC60

42.0 3.52 3.45 25.0 2.60 2.81 8.50

HD60

42.0 3.52 3.45 25.0 2.60 2.81 8.50

YHJD48S21S1

FC/MC/PC/UC60

48.0 3.40 4.13 37.0 2.76 3.97 7.70

FC/MC62

48.0 3.40 4.13 37.0 2.76 3.97 7.70

HC60

48.0 3.40 4.13 37.0 2.76 3.97 7.70

HD60

48.0 3.40 4.13 37.0 2.76 3.97 7.70

YHJD60S21S1

FC/MC62

58.0 3.46 4.91 40.0 2.36 4.90 7.70

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and

no supplemental electric heat operation.