York SPLIT-SYSTEM YHJD18 THRU 60 User Manual

Page 2

Advertising
background image

398612-YTG-B-0608

2

Johnson Controls Unitary Products

All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.

.

Physical and Electrical Data

MODEL

YHJD18

S21S1

YHJD24

S21S1

YHJD30

S21S1

YHJD36

S21S1

YHJD42

S21S1

YHJD48

S21S1

YHJD60

S21S1

Unit Supply Voltage

208-230V, 1

φ, 60Hz

Normal Voltage Range

1

187 to 252

Minimum Circuit Ampacity

9.9

13.1

17.7

19.8

24.9

40.1

40.1

Max. Overcurrent Device Amps

2

15

20

30

30

40

50

60

Min. Overcurrent Device Amps

3

15

15

20

20

25

45

45

Compressor Type

Recip

Recip

Recip

Recip

Recip

Scroll

Scroll

Compressor Amps

Rated Load

7.6

9.9

13.1

14.6

18.7

30.9

30.9

Locked Rotor

36

54

61

78

78

115

150

Crankcase Heater

Yes

Yes

Yes

Yes

Yes

No

No

Fan Motor Amps

Rated Load

0.5

1.5

1.4

1.5

1.5

1.5

1.5

Fan Diameter Inches

24

24

24

24

24

24

24

Fan Motor

Rated HP

1/15

1/10

1/4

1/4

1/4

1/4

1/4

Nominal RPM

850

825

1100

850

850

850

850

Nominal CFM

2050

2250

3700

3700

3600

3450

3600

Coil

Face Area Sq. Ft.

15.72

18.34

20.96

23.58

23.58

24.00

27.00

Rows Deep

1

1

1

1

1

2

2

Fin / Inches

22

22

22

22

22

22

22

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

3/4

3/4

7/8

7/8

7/8

1-1/8

Unit Charge (Lbs. - Oz.)

4

7 - 3

7 - 7

8 - 12

9 - 1

11 - 14

13 - 4

15 - 5

Charge Per Foot, Oz.

0.68

0.68

0.68

0.70

0.70

0.70

0.76

Operating Weight Lbs.

172

184

196

208

208

275

280

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15

feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

B

C

A

Unit

Model

Dimensions

(Inches)

Refrigerant Connection

Service Valve Size

A

1

1. Including Fan Guard.
* Adapter fitting required for 1-1/8” line set.

B

C

Liquid

Vapor

18

28

34

34

3/8”

3/4”

24

32

34

34

30

36

34

34

36

40

34

34

7/8”

42

40

34

34

48

40

34

34

60

40

34

34

1-1/8”