York SPLIT-SYSTEM YHJD18 THRU 60 User Manual

Page 14

Advertising
background image

398612-YTG-B-0608

14

Johnson Controls Unitary Products

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.

YHJD36S21S1

PV8*A12

FC/MC/PC/UC37A 34.0 3.66 2.68 20.0 2.56 2.31 8.65

PV9*A12

FC/MC/PC/UC37A 34.0 3.60 2.76 20.0 2.54 2.35 8.55

PV8*B16

FC/MC/PC/UC43B 33.0 3.74 2.61 20.0 2.62 2.23 8.80

PV8*C16

FC/MC/PC/UC43C 33.0 3.76 2.60 20.0 2.64 2.21 8.85

PV8*C20

FC/MC/PC/UC43C 33.0 3.70 2.64 20.0 2.60 2.25 8.75

P(C,V)9*B12

FC/MC/PC/UC43B 34.0 3.68 2.67 20.0 2.58 2.29 8.70

P(C,V)9*C16

FC/MC/PC/UC43C 33.0 3.74 2.61 20.0 2.62 2.23 8.80

P(C,V)9*C20

FC/MC/PC/UC43C 33.0 3.74 2.61 20.0 2.62 2.23 8.80

PV8*C16

FC/MC/PC/UC48C 33.0 3.78 2.57 20.0 2.66 2.19 8.90

PV8*C20

FC/MC/PC/UC48C 33.0 3.72 2.63 20.0 2.60 2.25 8.75

P(C,V)9*C16

FC/MC/PC/UC48C 33.0 3.76 2.60 20.0 2.64 2.21 8.85

P(C,V)9*C20

FC/MC/PC/UC48C 33.0 3.76 2.60 20.0 2.64 2.21 8.85

P(C,V)9*D20

FC/MC/PC/UC48D 33.0 3.76 2.60 20.0 2.64 2.21 8.85

PV8*C16

HC42

33.0 3.76 2.58 20.0 2.64 2.21 8.85

PV8*C20

HC42

33.0 3.72 2.63 20.0 2.60 2.25 8.75

P(C,V)9*C16

HC42

33.0 3.74 2.61 20.0 2.62 2.23 8.80

P(C,V)9*C20

HC42

33.0 3.76 2.60 20.0 2.64 2.21 8.85

YHJD42S21S1

PV8*C16

FC/MC/PC/UC48C 41.0 3.62 3.31 25.0 2.68 2.68 8.70

PV8*C20

FC/MC/PC/UC48C 41.0 3.64 3.30 24.0 2.70 2.64 8.75

P(C,V)9*C16

FC/MC/PC/UC48C 41.0 3.60 3.33 25.0 2.66 2.70 8.65

P(C,V)9*C20

FC/MC/PC/UC48C 41.0 3.62 3.31 25.0 2.68 2.68 8.70

P(C,V)9*D20

FC/MC/PC/UC48D 41.0 3.60 3.33 25.0 2.68 2.68 8.70

PV8*C16

FC/PC/UC60C

41.0 3.62 3.31 24.0 2.68 2.66 8.70

PV8*C20

FC/PC/UC60C

41.0 3.64 3.30 24.0 2.70 2.64 8.75

P(C,V)9*C16

FC/PC/UC60C

41.0 3.60 3.33 25.0 2.66 2.70 8.65

P(C,V)9*C20

FC/PC/UC60C

41.0 3.62 3.31 24.0 2.68 2.66 8.70

P(C,V)9*D20

FC/MC/PC/UC60D 41.0 3.62 3.31 25.0 2.68 2.68 8.70

YHJD48S21S1

PV8*C16

FC/PC/UC60C

48.0 3.42 4.06 37.0 2.76 3.92 7.80

PV8*C20

FC/PC/UC60C

48.0 3.44 4.04 37.0 2.78 3.92 8.00

P(C,V)9*C16

FC/PC/UC60C

47.0 3.40 4.05 37.0 2.76 3.97 7.80

P(C,V)9*C20

FC/PC/UC60C

48.0 3.42 4.06 37.0 2.76 3.94 8.00

P(C,V)9*D20

FC/MC/PC/UC60D 48.0 3.44 4.04 37.0 2.78 3.92 8.00

PV8*C20

FC/MC62D

48.0 3.44 4.04 37.0 2.78 3.92 8.00

P(C,V)9*C20

FC/MC62D

48.0 3.42 4.06 37.0 2.76 3.94 8.00

P(C,V)9*D20

FC/MC62D

48.0 3.44 4.04 37.0 2.78 3.92 8.00

YHJD60S21S1

PV8*C20

FC/MC62D

58.0 3.48 4.84 39.0 2.38 4.80 7.70

P(C,V)9*C20

FC/MC62D

57.0 3.48 4.79 38.0 2.38 4.73 7.70

P(C,V)9*D20

FC/MC62D

56.0 3.50 4.68 38.0 2.38 4.73 7.75

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and

no supplemental electric heat operation.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.

HEATING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT

MODEL

VARIABLE

SPEED

FURNACE

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD