Oxygen displays, Default nitrox settings, And po – SUUNTO VYTEC DS User Manual

Page 33: It remains in this setting until the o

Advertising
background image

31

on Nitrox use result in longer no-decompression
times and shallower maximum depths than div-
ing with air.

As a safety precaution the oxygen calculations
in the computer are made with an oxygen per-
centage of 1% + setO

2

% .

When the dive computer is set in Nitrox mode
the Dive Planning and Dive Simulation modes
both calculate with the O

2

% and PO

2

values

that are currently in the computer.

To set the Nitrox mixes refer to chapter 4.3 Set
Modes.

DEFAULT NITROX SETTINGS

In Nitrox mode the Vytec allows the user to set
1-3 nitrox mixes containing 21-99% oxygen.

In the Nitrox mode, the default setting for MIX1
is standard air (21% O

2

). It remains in this setting

until the O

2

% is adjusted to any other percentage of

oxygen (22% - 100%). The default setting for maxi-
mum oxygen partial pressure is 1.4 bar, however
you are able to set it in the range of 0.5 - 1.6 bar.

If unused, the computer will retain the manually
entered values for the oxygen percentage and
maximum oxygen partial pressure for MIX1 for
about two hours, after which it will revert to the
default settings.

MIX2 and MIX3 are by default set to OFF. To
set MIX2 and MIX 3 refer to chapter 3.4.4 Gas
change and multiple breathing mixes. Oxygen
percentages and maximum oxygen partial pres-
sures for MIX2 and MIX3 are stored permanent-
ly. If MIX2 and MIX3 are set OFF, the computer
will retain the manually entered values for the
oxygen percentage and maximum oxygen par-
tial pressure for MIX1 for about two hours, after
which it will revert to the default settings.

3.4.2. Oxygen Displays

If set to Nitrox mode the NITROX display,
with all labeled oxygen information and the

Fig. 3.19. Decompression
dive, above ceiling.
Note downward pointing
arrow, Er warning and
an audible alarm. You
should immediately (with-
in 3 minutes) descend to
or below ceiling.

DIVE TIME

T

C

B

m

STOP

CEILING

ASC TIME

AIR TIME

bar

Fig. 3.20. Ceiling and
Floor Zones. The Recom-
mended and Manadatory
Safety Stop zone lies
between 6m and 3m [20 ft
and 10ft].

3m / 10ft

6m / 18ft

CEILING

FLOOR

Fig. 3.21. Nitrox display.
Maximum depth based
on set O2% (21%) and
PO2 (1.4 bar) is 54.1 m
[177 ft].

PO2

O2%

OLF

m