Guarantree, Environment and recycling, Affix the type label of the heated mat her e – STIEBEL ELTRON FTD с 06.01.2003 User Manual

Page 11: 4 installation, 5 first start-up, 6 handover

Advertising
background image

11

English

Heated floor mat

FT
. ...
acc
. DIN 44576

T

ype-No

.:

.. .

. .

.

Pr

od.-No

.:

. .

. .

Rated v

oltage:

230 V

Rated po

w

er

:

...

W

Width of mat:

.,.. m

Length:

.,.. m

Total resistance:

... Ohm

Rated limit temper

ature:

90 ºC

Alter

nating v

oltage sustaining capability 4000

V

Insulation resistance checke

d

M E A S U R E D D A T A

BEFORE

laying the mat

AFTER

laying the mat

Total resistance
(Ohm)

Insulation
resistance
(megaohms)

Room:

Company:

Date / Signature:

Name :

Please be

war

e back pa

ge

!

Prod.-No

. :

3. Environment and
recycling

For guarantees please refer to the respective

terms and conditions of supply for your

country.

Please help us to protect the environment by

disposing of the packaging in accordance with

the national regulations for waste processing.

The installation, electrical connection

and first operation of this appliance

should be carried out by a qualified installer.

The company does not accept liability for

failure of any goods supplied which are not

installed in accordance with the

manufacturer's instructions.

Affix the type label of the heated mat her

e!

4. Guarantree

This creates an additional built-up height
including the heated mat of 6 to 8 mm. Apply
the desired covering after drying.

In the case of a poorly insulated subfloor or
one which is at risk from cracking, a floor
insulation board should if possible be laid
between the subfloor and the heated mat,
for the purpose of insulating or uncoupling
the heated mat.

2.4 Installation

The type label attached to the heated
floor mats must be filled in, using the

appropriate information, and must be
affixed to these installation instructions.

In the case of FTD series heated floor
mats, all fitted labels are to be removed.

2.4.1 Positioning of the floor
temperature probe

Prior to laying the heated mat, the
temperature probe (6) of the floor
thermostat must be laid. Attention is to be
paid to the following in this process:
The floor temperature probe is to be:
– laid in 11 mm empty trunking centrally

between two parallel heating conductors.
The empty trunking is to be recessed into
the substructure flush with the surface, and
sealed at the end;

– laid at a location which is representative

for the room (e.g. centre of the room), so
that the floor temperature which is set at
the control unit can be adhered to.
If the probe is installed at an unfavourable
location, false temperature measurements
by the probe and associated defective
control actions can occur as a consequence
of the following circumstances:

heat build-up - caused by additional
covering of the probe zone, e.g. by
erecting a cupboard

covering the largest area of the floor, but
not in the probe zone

continual draught through an open
window

For this, the operating and installation
instructions for the thermostat are to be
noted.

2.4.2 Laying the mat

Lay out the heated floor mat(s). To make
work easier, it is recommended that the
heated mat(s) is/are fixed in position using
securing pegs (5, special accessories).

By separating the reinforced glass fabric, it is
possible to lay several heating paths, accord-
ing to requirements (see

D

). Thus, for

example, the PTC connectors can also be
laid closer to the mains supply point
(thermostat). Attention must be paid to
ensuring that the heating paths do not cross
and that the heating lines are not bent or
twisted.

It is only the fabric (2) which may be
separated, the heating lines (1) must

not be severed under any circumstances.

After laying and any fixing of the heated mats,
the two PTC connectors (4) are to be laid
to the connection box of the thermostat, for
example through trunking.

During and after laying, the heated mats are
to be stepped on only to the extent which is
absolutely necessary, to avoid mechanical
damage. If necessary, special measures are to
be taken in this regard, for example wearing

shoes with rubber soles and placing and
moving the requisite equipment (tools) on
suitable supports.

2.4.3 Electrical connection

The electrical connection of the heated floor
mat is to be carried out in accordance with
the connection plan (

C

) in these installation

instructions.

Before and after the electrical connection of
the heated mat(s), the insulation resistance,
the continuity of current, and the resistance
value are to be measured.

The maximum permissible current in the
case of parallel connection of several heating
mats amounts to 10 A.

It is absolutely imperative to note the rated
current of the thermostat!

The protective braiding of the PTC
connectors serves to earth the

heated mats and must be connected to the
earth terminals of the thermostat.

2.5 First start-up

On the occasion of the first start-up, the
floor heating is to be heated up briefly
several times, since cracks in the top covering
can otherwise arise.

2.6 Handover

Explain the functions of the heated mat and
the thermostat to the user. Make him or her
aware of the safety instructions, in particular.
Hand over the operating and installation
instructions to the user, as well as the type
label. This is held to be a guarantee
document and must be retained.