English-53

English

OFF

H MIRROR

Horizontally

rotated

V MIRROR

Vertically

rotated

180

90L

90R

90 degree

rotation

270 degree

rotation

180 degree

rotation

OSD screen functions (continued)

CONFIGURATION2

SERIAL CONTROL

Select the communication interface (RS-232C, OPS (OPS-
compliant computer), or LAN) for the serial communication
function.
For connection of the signal cable, see page 24 to 28.

LAN SETTING

You can set the communication parameters for the LAN
network.
DHCP CLIENT

Select whether to use DHCP client or not.
Select OFF when not using it, and select ON when using
it.

IP ADDRESS

When DHCP CLIENT is OFF, set the IP address of the
monitor.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.

SUBNET MASK

When DHCP CLIENT is OFF, set the gateway mask. Set it
to 255.255.255.0 for normal use.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.

DEFAULT GATEWAY

When DHCP CLIENT is OFF, set the IP address of the
gateway router to externally connect the local area
including the monitor.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.

PORT

The port number (3007 and 63007) of the monitor is
displayed.

RESET

LAN settings are reset.

CONTROLLER SETTING

When controlling the monitor via a network using a 2-Series
control processor made by Crestron, set the communication
parameters.
CONTROLLER IP

Set the IP address of the control processor.

PORT NUMBER

Set the port number used for communication.

IP ID

Set the IP identifi cation number.

NOTE: For the detailed setting procedures, see the

operation manual of the control processor made by
Crestron.

CONTROL TIME OUT

When using remote control, the timeout for transmission
intervals among codes within the control command can be
set.
10 ms: Set the time out intervals to 10 milliseconds.
2 s:

Set the time out intervals to 2 seconds.

30 s: Set the time out intervals to 30 seconds.

MONITOR ID

ID numbers for wireless remote control are assigned to
MDT701S monitors that are multi-connected via RS-232C.
ID numbers 1 to 26 are selectable.

OSD TURN OFF

The OSD control menu will stay on as long as it is used.
The preset choices are 5 -120 seconds.

OSD H POSITION

You can adjust the horizontal position of the OSD menu.

OSD V POSITION

You can adjust the vertical position of the OSD menu.

OSD ROTATION

The OSD screen is rotated.