Candy FLGR 201 X User Manual

Page 44

Advertising
background image

Technical data

Table 2

Conversion with different gas to the regulation gas used in the factory.

Identical operations for both burners:
check the oven is disconnected from the electrical power supply
open the oven door completely
remove the bottom plate from the oven (fig. 4)
remove the burner by unscrewing screw “A”
remove injector “B” and replace it following the instructions shown in table 2 (check

there are no gas leaks on completing the operation)

reinstall the oven burner
put the plate back in place

FORNO

Ø Gas injector G30/G31 mm

0,73

Ø Gas injector G20/G31 mm

1,15

Ø Gas bypass G30/G31 mm

0,42

CAT. I3, I2, I2L sealed in factory
CAT. II2H3, II23 for gas G30/G31 screwed tight; for gas G20/G25
regulated for 0,72 kW capacity.

Rated capacity in kW

2,4

Minimum capacity in kW

0,72

Rated consumption of G30 in Kg/h

0,175

Rated consumption of G20 in m3/h

0,228

Rated consumption of G25 in m3/h

0,266

Position of ring nut G30/G31 mm

14

Air regulation (“X”) G20/G25 mm

5

Power supply voltage = 220V AC
Installed power = 1,.5kW (oven with electric grill)

Minimum air exchange needed for combustion is 4,8 m

3

/h.

Fig.4

42