JBOD System

Quick Start Guide

20

To establish the connection:
1.Connect the RAID system EXP port to the CH1 port of the JBOD1 using a

SAS cable.

2.To connect to the next JBOD, connect the EXP port of JBOD1 to the

CH1 port of JBOD2.

3.Follow the same procedures to connect the succeeding JBOD

enclosures.

4.To make a loop, connect the EXP port of JBOD3 to the CH1 port of

JBOD2.

5.Connect the EXP port of JBOD2 to the CH1 port of JBOD1.
6.Connect the EXP port of the RAID system to the CH1 port of JBOD3.
7.Set the chassis ID:

• A16R-FS (RAID) = 0
• A16R-SJ (JBOD1) = 1
• A16R-SJ (JBOD2) = 2
• A16R-SJ (JBOD3) = 3; and so forth for more JBOD enclosures

Note

For more information, see 2.3 SAS JBOD Enclosure Display on the

Accusys RAID GUI user’s manual.

To configure, see .