Accusys ExaRAID A16U-IS User Manual

Page 38

Advertising
background image

Accusys A16R/A16U-IS

36

The replacement

controller stops boot-

up with LCD

messages.

If the conflict configuration

can be resolved by overwrit-

ing the configuration of the

replacement controller, the

following LCD messages will

be displayed and waiting for

your confirmation by LCD ENT

button:

(H) CHK BC VERS: the two

controllers have different

boot code version.

(I) CHK FW VERS: the two

controllers have different firm-

ware code version.

(J) CHK BBM OPT: the two

controllers have different BBM

option.

(K) CHK SN UNEQ: the two

controllers belong to

different enclosures.

(L)CHK EXPAN NR: The two

controller have different

expansion numbers.

(M)CHK DISK NR: The

detected disk numbers are

not same of both controller.

Hard disk shows

Unknown state.

The configurations on the

hard disks cannot be recog-

nized by the controller.

Erase the configuration information

on the hard disks for your RAID

system to use the hard disks.

Disk group enters

degraded mode.

Member disks are not

available.

Use the Array Recovery

Utility to restore the disks to the

degraded disk group. See User’s

manual for more details.

Hard disk shows

Conflict state.

1. Cache unit size of the

controller is bigger than the

stripe size of the logical disk

on the hard disks.

2. A disk group with the same

disk group ID of the hard

disks.

3. incompatible firmware

version.

1. change the cache unit size.

2. use Array Roaming Utilities

to import the hard disks to form a

disk group with a new disk group ID.

See the User’s manual for more

details.

3. erase the configuration informa-

tion on the hard disks for your RAID

system to use the hard disks. Or,

contact your system supplier for

solutions.

Advertising