• Frequency—only appears when using a dual frequency transducer. This

allows you to choose a sonar operation frequency. You can choose 200

khz, 50 khz or Dual frequency (to alternate between the two frequencies).

Ultrascroll™/Scroll—adjusts the rate at which the Sonar Pages scrolls

from right to left. Ultrascroll (default) is used when you select a

scroll rate from 90% to 100%. Auto automatically adjusts the scroll rate

according to the boat’s speed.

• Depth line—adds a horizontal depth line across the screen that is used to

measure the depth of underwater objects. The depth of the line appears on

the right side of the line. Press up or down on the ROCKER to control the

position of the line on the Sonar Page. To turn the Depth Line off, press the

ROCKER up until the setting bar is all the way at the top of the range and

reads “Off”.

Depth lne

Zoom—sets a screen zoom scale. The following settings are available:
Off—turns off the Zoom function.
2x Zoom––displays the 2x zoomed picture.
4x Zoom––displays the 4x zoomed picture.
Btm (Bottom) lock––displays returns from the bottom up.

When using this setting, “BL” appears at the bottom of the screen.

Zoom View—available when you select a Zoom scale other than Off. You

can use the Zoom View setting to change the viewing range of a zoomed

display. Auto follows the water bottom. If the display is set to Bottom

lock, the Span setting adjusts how far off the bottom the unit shows data.

tools—controls the display of useful sonar tools. The following options are

available:

A-scope—when you turn on A-scope, a vertical flasher bar appears on

the far-right side of the screen. This flasher displays structure and

bottom returns much the same as the Flasher Page. The horizontal width

of the A-scope signal indicates the strength of the signal.

Color Bar—shows a gradient scale of the current Color Gain setting.
temp Graph—appears only if you have a temperature-capable

transducer. When on, this setting displays a temperature graph on the

bottom of a Sonar Page that matches the scrolling data.

Setup—opens the Sonar tab.
To adjust the range:

On the Sonar Page, press the up

RANGE key to decrease the range, or

press the down

RANGE key to increase the range.

The unit can be set to automatically track the bottom (Auto) or set to a user-

specified depth range.