Garmin SL60 User Manual

Page 120

Advertising
background image

Problem

Possible Cause

Action

Unit does not
power on

Open in power
supply circuit

Check circuit
breaker - reset if
necessary

Faulty electrical
wiring or
connection

Contact your
dealer to perform
electrical system
test

No GPS signal
reception

Obstructed signal
path

Move aircraft out
of hangar or away
from buildings to
provide an
unobstructed view
of the sky for the
antenna

Incorrect seed
position, time, or
UTC differential
entered

Check these
settings, if
necessary

If using a wrong
antenna: faulty
external antenna,
wiring, or
connections

Contact your
dealer to check the
antenna and other
wiring

Search for nearest
waypoints reveals
too few or wrong
types of waypoints

Incorrect selection
of waypoint types
to show after
search

Check “Airspace
Setup” function
and verify that the
desired waypoint
type to search is
“ON”

Position fix seems
inaccurate

Wrong seed
position

Re-enter seed
position

Waypoints
sequencing is
erratic

Direct-To entry
option setting may
not be correct

If you are flying
Direct-To, the
option should be
set to “May Clear”,
see page 74

Wrong bearing
and track values

Incorrect magnetic
variation entered

Check Magnetic
Var option - select
“Automatic” or
enter correct value

Can’t change
active frequency

Comm Radio not
communicating

Contact dealer.

110

Troubleshooting