Wiring connections, Electrical service, Wiring connections configuration connector – Spicer TPCS (Tire Pressure Control System) Service Manual User Manual

Page 16: Relay and power connections, Vehicle grounds, Lamp switch

Advertising
background image

16

Wiring Connections

Configuration Connector

This connector initializes the Electronic Control Unit for
the current vehicle configuration (see Figure 9). De-
pending on application, factory supplied jumper con-
nector may be provided.

Relay and Power Connections

Figure 7 shows the terminal connections to the relay
and the vehicle power panel. The connections must be
made as shown. The relay lugs plug into the bottom of
the relay sockets.

Vehicle Grounds

There are three ground terminals that must be secured
to the vehicle chassis. The ground terminals are for the
Electronic Control Unit, Operator Control Panel and
vehicle interface. Figure 3 shows the three grounds and
their attachment points.

Caution: The battery and the switched ignition are
fused individually with a circuit breaker or a fuse.
(See Figure 7 for power requirements.)

Lamp Switch

The lamp wire provides back-lighting for the Operator
Control Panel keypad and dims the display. Some
vehicles use a separate switch to control intensity. This
may be connected to the headlamp circuit, a day time
running light (DRL) system or a separate switch. This
is a switched input and cannot be connected directly to
the dimmer switch.

Electrical Service

!

Figure 7 Terminal Connections

RSP 3

VBATT 2

VBATT 1

RLY1ENA

Relay Lugs

Vehicle Power Panel

VBATT

SWACC 3

1

4

2

5

3

Relay

Top View (relay side)

To battery
20 amp fuse

To ignition switch
5 amp fuse

GND 8
(vehicle ground)

LAMP 2

Lamp Switch

Normal
(Bright)

Dim

To

headlamp

or

No Connection