Operator controls, Figure 40 entering the programming sequence – Spicer TPCS (Tire Pressure Control System) Service Manual User Manual

Page 56

Advertising
background image

56

Figure 40 Entering the Programming Sequence

Operator Controls

mph

kph

bar

psi

Tire Pressure Control

mph

kph

bar

psi

Tire Pressure Control

bar

psi

L / U

SELECT

+

flashing “bar” or “psi”

indicates you have

entered programming

Press at the same

time to enter

programming

L / U

or

Press to record a selection
in memory and move to
the next step

Toggle

between metric

and English

EMER

Make selection

SELECT

L / U

+

Press at the same

time to exit

programming

SELECT

bar

psi

L / U

SELECT

Enter programming

SELECT

+

SELECT

L / U

or

EMER

Press SELECT six times to go to step 7

Press to set highway

unloaded drive pressure

L / U

SELECT

Exit programming

Example for Step 7 Programming (see programming quick reference chart)

SELECT

+

SELECT

+

+

SELECT

+

SELECT

+

SELECT

+

+

down

arrow

up

arrow

Example for Step 1 Programming (see programming quick reference chart)

down

arrow

up

arrow

Advertising