VEGA VEGABAR 17 User Manual

Page 27

Advertising
background image

A

verage temperature coefficient of the span

typ. < 0.2 %/10 K

Long-term stability (according to DIN 16086, DINV 19259-1 and IEC 60770-1)

L

ong-term drift of the zero signal

6)

<

0.2 %/

year

Ambient conditions

A

mbient temperature (note temperature derating!)

-

C

able outlet

-20 … +80 °C (-4 … +176 °F)

-

R

ound plug connector M12 x 1

-25 … +80 °C (-13 … +176 °F)

-

A

ngled plug connector according to

ISO

4400

-40 … +80 °C (-40 … +176 °F)

-

T

erminal housing

-50 … +80 °C (-58 … +176 °F)

-

with cooling element

-20 … +80 °C (-4 … +176 °F)

2

1

55°C

(131°F)

80°C

(176°F)

130°C

(266°F)

150°C

(302°F)

Fig. 14: Temperature derating VEGABAR 17

1

Ambient temperature

2

Process temperature

S

torage and transport temperature

-

S

tandard

-30 … +100 °C (-22 … +212 °F)

-

with cooling element

-20 … +100 °C (-4 … +212 °F)

Process conditions

P

roduct temperature

-

S

tandard

-30 … +100 °C (-22 … +212 °F)

-

additional

-30 … +125 °C (-22 … +257 °F)

-

with cooling element

-20 … +150 °C (-4 … +302 °F)

-

M

easuring ranges from 400 bar

-30 … +70 °C (-22 … +158 °F)

S

hock resistance

-

V

ersion with terminal housing

600

g according to IEC 60068-2-27 (mechanical

shock)

6)

U

nder reference conditions, relating to the adjusted span.

VEGABAR

17

27

9 S

upplement

27636

-

EN

-120531