background image

4 M

ounting

4

.1 General instructions

N

ote the following points when selecting the installation

location.

l

S

ideways movements of the transmitter can cause

measurement errors

à Therefore, mount VEGAWELL 72 in a calm area or in a

suitable protective tube

Information:
W

e recommend the measuring instrument holder from the

VEGA

line of accessories (article no. BARMONT.B) for

fastening VEGAWELL 72.

l

T

he protective cover prevents mechanical damage to the

measuring cell. It should only be removed when the sensor
is deployed in extremely polluted water.

N

ote the following item for pressure compensation:

l

T

he connection cable has a capillary for atmospheric

pressure compensation

à Therefore lead the cable end into a dry space or directly

into a suitable connection housing.

Information:
VEGA

recommends VEGABOX 02 or VEGADIS 12 as

connection housing. Both contain the terminals as well as a

lter element for pressure compensation. For mounting

outdoors, a suitable protective cover is available. On VEGA-
WELL

72

with plastic housing, the terminals and the filter

element are already integrated in the plastic housing.

Mounting position

Pressure compensation

Mounting example

12

VEGAWELL

72 • 4 … 20

mA/HART