3 wiring plan – VEGA VEGADIS 12 User Manual
Page 13
5.3 Wiring plan
5
1
2
3
4
Fig. 4: Wire assignment, connection cable
1
brown (+): to power supply or to the processing system
2
blue (-): to power supply or to the processing system
3
yellow: for adjustment information of VEGADIS 12
4
Screen
5
Breather capillaries with filter element
+
–
+
–
VEGADIS 12
TRANSMITTER
+
4...20mA
+
NOT USED
8 7 6
5 12
11 10
1 2 3
-
OPERATE
ti
ZERO
SPAN
TRANSMITTER
3
4
5
1
2
Fig. 5: Terminal assignment, VEGADIS 12
1
To power supply or the processing system
2
Control instrument (4 … 20 mA measurement)
3
Screen
1)
4
Breather capillaries
5
Suspension cable
1)
Connect screen to ground terminal. Connect ground terminal on the outside
of the housing as prescribed. The two terminals are galvanically connected.
Wire assignment, connection
cable pressure transmitter
Connection of VEGADIS 12
without display
VEGADIS 12
13
Connecting to power supply
20591
-EN
-071128