VEGAPULS 41 – 4 … 20 mA

53

26620-EN-041227

Technical data

Accuracy

1)

(typical values under reference conditions, all statements relate to the nominal measuring
range)

Characteristics

linear

Resolution, general

max. 1 mm

Resolution of the output signal

see diagram

Characteristics

1)

(typical values under reference conditions, all statements relate to the nominal measuring
range)

Min. span between

full and empty

> 10 mm (recommended > 50 mm)

Frequency

26 GHz technology

Intervals

- two-wire sensor (4 … 20 mA)

1 s

- two-wire sensor (digital)

0.6 s

- four-wire sensor

0.5 s

Beam angle (at -3 dB)

22°

Adjustment time (response time)

2)

> 1 s (dependent on the parameter adjustment)

Influence of the process temperature

cannot be measured at 0 bar;
at 5 bar 0.004 %/10 °K;
at 40 bar 0.03 %/10 °K

Influence of the process pressure

0.0265 %/bar

Adjustment time

2)

> 1 s (dependent on the parameter adjustment)

Emitted radar power (average)

0.717 µW

Received average emitted power

3)

- distance 1 m

0.4 … 3.2 nW per cm² (0.4 … 3.2 x 10

-9

W/cm²)

- distance 5 m

0.02 … 0.13 nW per cm²

1)

Similar to DIN 16 086, reference conditions acc. to IEC 770, e.g.
temperature 15 °C … 35 °C; moisture 45 % … 75 %; pressure 860 mbar … 1060 mbar

2)

The adjustment time (also actuating time, response time or adjustment period) is the time required by the
sensor to output the correct level (with max. 10% deviation) after a sudden level change.

3)

Average emitted power (electromagnetic energy) received by a body per cm² directly in front of the antenna.
The received emitted power depends on the antenna version and the distance.

0,5 m

10 m

10 mm

5 mm

-5 mm

-10 mm