VEGA VEGAPULS 41 4 … 20 mA; HART compact sensor User Manual

Page 54

Advertising
background image

54

VEGAPULS 41 – 4 … 20 mA

26620-EN-041227

Technical data

Ambient conditions

Vessel pressure

-100 … 300 kPa (-1 … 3 bar)

Ambient temperature on the housing

- 4 … 20 mA two-wire sensor

-40°C … +80°C

- 4 … 20 mA four-wire sensor

-40°C … +80°C

- 4 … 20 mA four-wire sensor Ex d ia

-40°C … +60°C

Process temperature (flange temp.)

-40°C … +130°C

Storage and transport temperature

-60°C … +80°C

Protection

IP 66 and IP 67

Protection class

- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Ex-technical data

Comprehensive data in the safety instructions manual (yellow binder)

WHG approvals

VEGAPULS 41 radar sensors are approved as part of an overfill protection system for
stationary vessels storing water-endangering liquids.

Materials

Housing

PBT (Valox) or
Aluminium die casting (GD-AlSi 10 Mg)

Connection housing with Exd version

Aluminium mould casting (GK-AlSi 7 Mg)

Process flange

PVDF

Antenna (wetted parts)

TFM-PTFE

Connection cables

Two-wire sensors

power supply and signal via one
two-wire cable

Four-wire sensors

power supply and signal separated

Electrical connection

- cable entry

for Aluminium and plastic housing:
one cable entry (four-wire: two cable entries)
and spring-loaded terminal connection
up to max. 2.5 mm

2

wire cross-section

- plug connection

optional for plastic housing:
four-pole, polarity reversal-proof screwed plug
connection (four-wire: tow plug connections)

Cable entry

- ia terminal compartment

1 … 2 x M20 x 1.5 (cable-ø 5 … 9 mm) or
1 … 2 x ½“ NPT EEx d (cable-ø 3.1 … 8.7 mm
or 0.12 … 0.34 inch)

- Exd terminal compartment

(pressure-tight encapsulated)

1 x½“ NPT EEx d (cable-ø 3.1 … 8.7 mm or
0.12 … 0.34 inch)

Ground connection

max. 4 mm²

Intermediate housing between

process flange and housing

1.4435

Advertising