VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - four-wire User Manual
Page 13
1
3
2
100%
0%
4
Fig. 3: Measuring range (operating range) and max. measuring distance
1
full
2
empty (max. measuring distance)
3
Measuring range
4
Reference plane
T
he emitted radar impulses of VEGAPULS 63 are electromagnetic
waves. The polarisation plane is the direction of the electrical share.
T
heir position is marked on the instrument.
1
Fig. 4: Position of the polarisation plane of VEGAPULS 63
1
Marking hole
M
ake sure that all parts of the instrument exposed to the process, in
particular the sensor element, process seal and process fitting, are
suitable for the existing process conditions. These include above all
the process pressure, process temperature as well as the chemical
properties of the medium.
Y
ou can find the specifications in chapter "Technical data" and on the
type label.
Polarisation plane
Suitability for the pro-
cess conditions
VEGAPULS
63 • 4 … 20
mA/HART - four-wire
13
4 M
ounting
28441
-EN
-120530