VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - four-wire User Manual

Page 19

Advertising
background image

100%

0%

1

> 300 mm

Fig. 13: VEGAPULS 63 in a bypass tube. The polarisation marking on the
process fitting must be in one plane with the tube holes or the tube connection
openings.

1

Marking of the polarisation direction

W

hen the sensor is mounted on a bypass tube, the distance from

VEGAPULS

63

to the upper tube connection should be approx.

300

mm (11.81 in) or more. In case of extremely rough tube inner

walls, you should use an inserted tube (tube in tube) or a radar sensor
with tube antenna.

Information:
W

ith VEGAPULS 63 in flange version, the polarisation plane is always

in the center between two flange holes.

1

2

3

4

Fig. 14: Polarisation level with flange version, view from top on the sensor and
bypass tube. The sensor housing is not shown.

1

Position of the polarisation level

2

Flange hole

3

Upper tube connection

4

Polarisation marking

VEGAPULS

63 • 4 … 20

mA/HART - four-wire

19

4 M

ounting

28441

-EN

-120530

Advertising