VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - four-wire User Manual

Page 49

Advertising
background image

A

verage temperature coefficient of the zero

signal (temperature error)

0.03 %/10 K

Influence of the superimposed gas and pressure to the accuracy
T

he spreading speed of the radar impulses in gas or vapour above the product is reduced by high

pressures. This effect depends on the superimposed gas or vapour and increases with low
temperatures. The following chart shows the deviation caused by some typical gases or vapours.
T

he stated values refer to the distance. Positive values mean that the measured distance is too

high, negative values that the measured distance is too small.

Gas phase

Temperature

1

bar/14.5 psig

10

bar/145 psig

50

bar/725 psig

A

ir/Nitrogen

20 °C/68 °F

0.00 %

0.22 %

1.2 %

A

ir/Nitrogen

200 °C/392 °F

0.00 %

0.13 %

0.74 %

H

ydrogen

20 °C/68 °F

-0.01 %

0.10 %

0.61 %

H

ydrogen

200 °C/392 °F

-0.02 %

0.05 %

0.37 %

W

ater (saturated

steam)

100 °C/212 °F

0.20 %

-

-

W

ater (saturated

steam)

180 °C/356 °F

-

2.1 %

-

Ambient conditions

A

mbient, storage and transport temperature

-40 … +70 °C (-40 … +158 °F)

Process conditions

F

or the pressure stages of the vessel pressure, you also have to note the specifications on the type

label. Always the lowest value is applicable.

P

ressure stage, depending on the process fitting

-

B

olting according to DIN 11851 and

11864-2,

hygienic fitting LA and LB

PN

16

vessel pressure depending on the process fitting

-

ange up to 2" (from 300 lb)/DN 50

-100 … 1600

kPa/-1 … 16 bar (-14.5 … 232 psig)

-

F

lange from 3" (from 300 lb), DN 80

-20 … 1600

kPa/-0.2 … 16 bar (-2.9 … 232 psig)

-

T

uchenhagen Varivent

-100 … 1000

kPa/-1 … 10 bar (-14.5 … 145 psig)

-

SMS

-100 … 600

kPa/-1 … 6 bar (-14.5 … 87 psig)

V

essel pressure relating to the flange nom-

inal stage

see supplementary instructions manual "Flanges
according to DIN-EN-ASME-JIS
"

P

rocess temperature, depending on the material of the antenna encapsulation (measured on the

process fitting)

-

TFM-PTFE

encapsulated

-40 … +150 °C (-40 … +302 °F)

-

TFM-PTFE

encapsulated (low temper-

ature version)

9)

-170 … +150 °C (-274 … +302 °F)

-

PFA

encapsulated

-40 … +150 °C (-40 … +302 °F)

9)

N

ot suitable for SIL applications.

VEGAPULS

63 • 4 … 20

mA/HART - four-wire

49

10 A

nnex

28441

-EN