Electrical connection – VEGA VEGAPULS 54K enamel User Manual

Page 26

Advertising
background image

26

VEGAPULS 54K enamel

24 101-EN-041227

Electrical connection

VEGAPULS 54K Ex (loop powered) with pressure-tight encapsulated
connection compartment on active PLC

• Two-wire technology, supply via the cable from active PLC to Exd connection housing for

operation in Ex-Zone 1 (VEGAPULS …K Ex) or Ex-Zone 0 (VEGAPULS …K Ex0).

• Output signal 4 … 20 mA (passive).
• Measured value display integrated in the sensor.
• Optional external indicating instrument with analogue and digital display (can be mounted

up to 25 m away from the sensor in Ex area).

• Adjustment with PC, HART

®

handheld or adjustment module MINICOM (can be plugged into

the sensor or into the external indicating instrument VEGADIS 50).

1)

If the resistance of the processing systems
connected to the 4 … 20 mA signal output is less
than 200

Ω, a resistor must be connected to the

connection cable during adjustment to get a loop
resistance between 250

Ω up to 300 Ω.

The digital adjustment signal would otherwise be
severely damped or short-circuited due to
insufficient resistance of the connected process-
ing system. Digital communication with the PC or
the HART

®

handheld would not be ensured.

4 … 20 mA

2

2

2

2

4

1)

EEx d ia

EEx e

VEGA-
CONNECT 2

VEGADIS 50 Ex

passive

2)

Ex area

Non Ex area

HART

®

handheld

PLC (active)

2)

4 … 20 mA passive means that the sensor
consumes a level-dependent current of
4 … 20 mA. The sensor reacts electrically like a
varying resistor (consumer) to the PLC.

Advertising