3 adjustment, 2 application features, Continuous and accurate – VEGA VEGAPULS 54K enamel User Manual

Page 6: Handheld

Advertising
background image

6

VEGAPULS 54K enamel

24 101-EN-041227

Product description

Rugged and abrasionproof

• non-contact
• high-resistance materials

Exact and reliable

• meas. resolution 1 mm
• unaffected by noise, vapours, dusts, gas

compositions and inert gas stratification

• unaffected by varying density and tem-

perature of the medium

• measurement in pressures of -1 … 16 bar

and product temperatures of
-40°C … 200°C

Communicative

• integrated measured value display
• optional display module separate from

sensor

• connection to all BUS systems: Interbus S,

Modbus, Siemens 3964R, Profibus DP,
Profibus FMS, ASCII

• adjustment from the PLC level with the PC
• adjustment with HART

®

handheld

• adjustment with detachable adjustment

module, pluggable in the sensor or in the
external display

Approvals

• CENELEC, ATEX, PTB, FM, CSA, ABS,

LRS, GL, LR, FCC

1.3 Adjustment

Every measurement set-up is unique. For
that reason, every radar sensor needs some
basic information on the application and the
environment, e.g. which level means "empty“
and which level "full“. Beside this "empty and
full adjustment“, many other settings and
adjustments are possible with VEGAPULS
radar sensors.

The adjustment and parameter setting of
radar sensors is carried out with
- the PC
- the detachable adjustment module MINI-

COM

- the HART

®

handheld

Temperature influence: Temperature error absolutely
zero (e.g. at 500°C 0.018 %)

Pressure influence: Error with pressure increase very
low (e.g. at 50 bar 1.44 %)

100

500

1000

1300 ˚C

0

0

0,01

0,02

0,03

%

0,018 %

0,023 %

10

0

0

5

%

1,44 %

2,8 %

10

50

20

30

40

60

100

70

80

90

110

120

130

140

bar

0,29 %

3,89 %

Continuous and accurate

Unaffected by temperature, pressure and
atmosphere content, VEGAPULS radar sen-
sors measure quickly and accurately the
levels of widely varying products.

VEGAPULS 50 sensors allow radar level
measurement in plants where they were it
was hitherto unthinkable because of high
costs.

1.2 Application features

Applications

• level measurement of any liquid, limited use

in solids

• measurement also in vacuum
• all slightly conductive materials and all

substances with a dielectric constant > 2.0
can be measured

• measuring range 0 … 20 m

Two-wire technology

• power supply and output signal on one

two-wire cable (Loop powered)

• 4 … 20 mA output signal

Advertising