VEGA VEGAFLEX 54K User Manual

Page 9

Advertising
background image

VEGAFLEX 54K

9

Product description

Accuracy

(under reference conditions acc. to IEC 770 - relating to the max. meas. range)

Linearity error

< 0.1 %

Temperature drift

0.015 %/10 K

Resolution of the 4 … 20 mA signal

0.025 % of range (DA converter)

Resolution

1 mm

Characteristics

Min. span between
full and empty adjustment
- analogue output signal

10 mm

Ambient conditions

Vessel pressure

-1 … 40 bar

Ambient temperature on the housing

-40°C … +60°C

Process temperature

-40°C … +150°C

Storage and transport temperature

-40°C … +80°C

Protection

IP 66/IP 67 (meets both protection standards)

Protection class
- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Max. tensile load

cable ø

4 mm: 1 KN

rod ø

8 mm: 1 KN

Min. dielectric constant

ε

r

> 1.7

Process fittings

VEGAFLEX 54

G1 A, 1" NPT, G 1

1

/

2

A, 1

1

/

2

" NPT

of 1.4435 (stst; 316L) or
Hastelloy C22 plated

Ex technical data

Ex-Zone 0 acc. to ATEX II 1 G or II 1/2 G or II 2 G EEx ia II C T6, ATEX II 1/2 G or II 2 G
EEx d ia II C T6 and ATEX II 1/2 G
The permissible operating data of the VEGAFLEX sensors for Ex areas are listed in the
certificate.

Materials

Housing

PBT (Valox) or
Aluminium (powder-coated)

Rod

1.4435 (stst; 316L) or Hastelloy

Cable

1.4401 (stst; 316L)