2
1
3
Fig. 8: Position of the screws and locking ring on the example of the plastic
housing
1
Screw check angle
2
Screw locking ring
3
Locking ring
2
Open the locking ring with the pliers and remove it
3
With Aluminium double chamber and stainless steel
housing loosen the screw on the socket
1
Fig. 9: Double chamber housing
1
Position of the screw
4
Remove the housing
4
.4 Mounting steps version A
Danger:
Individual wires of the transducer cable have a voltage of
approx. 70 V during operation (see chapter "Mounting
preparations"). There is danger of electric shocks! Carry out
the mounting steps only in the complete absence of line
voltage.
Dismount the pre-
vious emitting elec-
tronics
10
Emitting electronics - for VEGASON 64, 65, 66
Mounting
30205
-EN