.6 Mounting steps version C/D

Danger:
The individual wires of the transducer cable have a voltage of
approx. 70 V during operation (see chapter "Mounting
preparations
"). There is danger of electric shocks! Carry out
the mounting steps only in the complete absence of line
voltage.

Warning:
Idle condition
must be provided before separating the
transducer cable. Non-observance will cause damage of the
electronics!

Proceed as follows:

à Loosen the plug connection on the socket of the previous

emitting electronics

1

2

3

Fig. 14: Dismounting the previous emitting electronics
1

Emitting electronics with socket

2

Plug connector

3

Connection piece swivelling holder or transducer tube

à Provide the plug connection to the socket of the new

emitting electronics

Dismount the pre-
vious emitting elec-
tronics

Insert the new emitting elec-
tronics

Emitting electronics - for VEGASON 64, 65, 66