VEGA VEGASON 66 Emitting electronics User Manual
Page 11
Advertising
Proceed as follows:
1
Loosen the Torx screws on the housing socket with the
suitable key T15
2
Remove the previous emitting electronics from the flange
adapter
1
2
3
Fig. 10: Dismounting the previous emitting electronics
1
Emitting electronics
2
Torx screws T15 (4 pcs.)
3
Flange adapter
3
Remove the plug connector to the transducer on the lower
side of the emitting electronics, therefore press the lug
Warning:
Idle condition must be provided before separating the
transducer cable. Non-observance will cause damage of the
electronics!
Proceed as follows:
1
Plug the new emitting electronics to the plug connector
Insert the new emitting elec-
tronics
Emitting electronics - for VEGASON 64, 65, 66
11
Mounting
30205
-
EN
-070510
Advertising