VEGA VEGASON 66 Emitting electronics User Manual

Page 11

Advertising
background image

Proceed as follows:

1

Loosen the Torx screws on the housing socket with the
suitable key T15

2

Remove the previous emitting electronics from the flange
adapter

1

2

3

Fig. 10: Dismounting the previous emitting electronics
1

Emitting electronics

2

Torx screws T15 (4 pcs.)

3

Flange adapter

3

Remove the plug connector to the transducer on the lower
side of the emitting electronics, therefore press the lug

Warning:
Idle condition
must be provided before separating the
transducer cable. Non-observance will cause damage of the
electronics!

Proceed as follows:

1

Plug the new emitting electronics to the plug connector

Insert the new emitting elec-
tronics

Emitting electronics - for VEGASON 64, 65, 66

11

Mounting

30205

-

EN