VEGA VEGASON 65 4 … 20 mA_HART four-wire User Manual

Page 14

Advertising
background image

3

I

nsert the transducer tube in the requested length from below into

the swivelling holder

4

F

asten with screws (4); torque max. 10 Nm

5

R

emove the plug from below out of the instrument housing and

plug it into the socket of the transducer tube

6

P

lug the electronics housing to the transducer tube. Do not

squeeze any cables. The housing is in the correct position, if the
lower notch (2) of the transducer tube is no longer visible

7

T

ighten the screws (5) on the housing moderately with an Allen

wrench (size 4)

8

L

oosen terminal screw of the swivelling holder (3) with a fork

spanner (SW 13)

9

D

irect the sensor with the swivelling holder to the measured

product

10 F

asten the swivelling holder with screw (3), torque max. 20 Nm

11 S

ecure screw (3) with lacquer or similar to ensure permanent

tightness of the swivelling holder

12 R

otate the housing in such a way that the cable entry points

downwards (moisture can drain off). Fasten the housing with
screws (5); torque Aluminium housing max. 5 Nm, torque plastic
housing max. 2 Nm

1

2

3

4

5

Fig. 5: Mounting - Version B
1

Groove to lock the housing

2

Notch

3

Screw of swivelling holder (hexagon SW 13)

4

Grub screw, fixing ring (hexagon spanner - size 4)

5

Terminal screws, housing (hexagon spanner - size 4)

14

VEGASON

65 • 4 … 20

mA/HART four-wire

4 M

ounting

28782

-EN

-081127

Advertising