VEGA VEGASON 65 4 … 20 mA_HART four-wire User Manual

Page 17

Advertising
background image

5

P

lug the connection head to the transducer tube. Do not squeeze

any cables. The cylinder is in the correct position, if the lower
notch (2) of the transducer tube is no longer visible

1

2

3

4

Fig. 8: Mounting - Version D
1

Groove for locking the connection head

2

Notch

3

Hexagon nut SW 46

4

Terminal screws, connection head (hexagon spanner - size 4)

6

T

ighten the screws (4) on the cylinder moderately with an Allen

wrench (size 4)

7

R

otate the connection head in such a way that the cable entry

points downwards (moisture can drain off). Fasten the cylinder
with screws (4); torque max. 5 Nm

8

I

nsert the plug at the end of the transducer cable into the socket on

the remote electronics

1

2

3

Fig. 9: Plug connector between transducer and socket of electronics housing
1

Socket electronics housing

2

Plug connector

3

Connection piece, transducer tube

VEGASON

65 • 4 … 20

mA/HART four-wire

17

4 M

ounting

28782

-

EN

-081127

Advertising