1 short description, 2 insert indicating and adjustment module – VEGA VEGASON 65 4 … 20 mA_HART four-wire User Manual

Page 29

Advertising
background image

6 Set up with the indicating and adjustment

module PLICSCOM

6.1 Short description

T

he indicating and adjustment module PLICSCOM is used for

measured value display, adjustment and diagnosis. It can be mounted
in the following housing versions and instruments:

l

A

ll sensors of the plics

®

instrument family, in the single as well as

in the double chamber housing (optionally in the electronics or
connection compartment)

l

E

xternal indicating and adjustment unit VEGADIS 61

W

ith hardware version …- 01 or higher of PLICSCOM as well as the

respective sensor, an integrated backlight can be switched on via the
adjustment menu. The hardware version is stated on the type label of
the PLICSCOM or the sensor electronics.

Information:
T

his function is available at a later date for instruments with StEx,

WHG

or ship approval as well as country-specific approvals such as

those according to FM or CSA.

Note:
Y

ou can find detailed information on the adjustment in the operating

instructions manual of the indicating and adjustment module
PLICSCOM.

6.2 Insert indicating and adjustment module

T

he indicating and adjustment module can be inserted into the sensor

and removed again at any time. It is not necessary to interrupt the
power supply.

P

roceed as follows:

1

U

nscrew the housing cover

2

P

lace the indicating and adjustment module in the desired position

on the electronics (you can choose any one of four different
positions - each displaced by 90°)

3

P

ress the indicating and adjustment module onto the electronics

and turn it to the right until it snaps in.

4

S

crew housing cover with inspection window tightly back on

R

emoval is carried out in reverse order.

T

he indicating and adjustment module is powered by the sensor, an

additional connection is not necessary.

Function/Configuration

Mount/Dismount indicat-
ing and adjustment
module

VEGASON

65 • 4 … 20

mA/HART four-wire

29

6 S

et up with the indicating and adjustment module PLICSCOM

28782

-

EN

-081127

Advertising